644
Protocol Specific Features |
|
HART |
FOUNDATIONTM
Fieldbus
|
|
Rugged EMC performance for reliable measurements – meets
NAMUR NE 21
standards |
Standard function blocks: 2 Analog Inputs, 1
PID and 1
Backup Link Active Scheduler (LAS) |
|
Custom Alarm and Saturation Levels |
Regulatory Control Suite 1 PID
offers value and flexibility when generating control strategies. |
|
Available in Head or Rail Mount Form |
FISCO Approvals for fieldbus installations |
|
Hardware Alarm Switch |
PlantWeb Alerts
Available |
|
Multi-Dropped for HART Control Systems
|
18-bit analog-to-digital converter with
ambient temperature compensation enhances performance and process
quality |
|
Supply Voltage: 12 -
42.2V |
Supply Voltage: 9 - 32V |
Rosemount 644 FOUNDATIONTM
Fieldbus Key
Specifications |
| Accuracy |
+ 0.15° C (+0.27° F) for Pt100 RTD |
| Ambient Temperature Effects |
0.003°C per 1.0°C change in ambient temperature for Pt100 RTD |
| 2-year Stability |
+ 0.15% of reading or 0.15° C,
whichever is greater |
| Inputs |
2-, 3-, and 4-wire RTDs, thermocouple, millivolt, ohm |
| Vibration Approvals |
60 - 500 Hz at 3 g
|
|
|
|
|
Emerson Process Management,
Rosemount Division, 8200 Market Blvd.
Chanhassen, MN USA 55317
North America: 1-800-999-9307 International:
952-906-8888 Fax: 952-949-7001
|